25 Pound Handi-Pak
       
BARE & TINNED COPPER WIRE
BARE COPPER
SOFT, MEDIUM OR HARD DRAWN

DESCRIPTION
Bare copper conductors available in various tempers and sizes. Coated copper conductors, solid or stranded, available in various sizes but in soft temper only.

APPLICATION
Used in overhead electrical transmission and distribution, for grounding electrical systems where high conductivity and flexibility is required. Suitable for numerous other applications.

SPECIFICATION
ASTM B-1 Hard-Drawn Copper Wire
ASTM B-2 Medium-Hard-Drawn Copper Wire
ASTM B-3 Soft or Annealed Copper Wire
ASTM B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
ASTM B-33 Tinned Soft or Annealed Copper Wire
BARE & TINNED COPPER WIRE
Size Individual Wire Dia. Weight (Lbs.)/1000 Ft. Size Individual Wire Dia. Weight (Lbs.)/ 1000 Ft.
SOLID
30 .0100 .30 8 .1285 49.98
28 .0126 .48 6 .1620 79.46
26 .0159 .77 4 .2043 126.40
22 .0254 1.94 3 .2294 159.30
20 .0320 3.10 2 .2576 200.90
18 .0403 4.29 1 .2893 253.30
16 .0508 7.81 1/0 .3249 319.40
14 .0641 12.43 2/0 .3648 402.80
12 .0808 19.77 3/0 .4096 507.80
10 .1019 31.43 4/0 .4600 640.50
 
Size Individual Wire Dia. Weight (Lbs.)/ 1000 Ft. Size Individual Wire Dia. Weight (Lbs.)/ 1000 Ft.
STRANDED - Concentric
8-7/W .0486 51.0 250-37/W .0822 771.9
6-7/W .0612 81.1 300-19/W .1257 926.3
4-7/W .0772 128.9 300-37/W .0900 926.3
2-7/W .1093 204.9 350-19/W .1357 1081.0
1-7/W .1093 258.4 350-37/W .0973 1081.0
1/0-7/W .1228 325.8 400-19/W .1451 1235.0
1/0-19/W .0745 325.8 400-37/W .1040 1235.0
2/0-7/W .1379 410.9 500-37/W .1162 1544.0
2/0-19/W .0837 410.9 750-61/W .1109 2316.0
3/0-7/W .1548 518.1 1000-61/W .1280 3088.0
3/0-19/W .0940 518.1 1250-61/W .1431 3859.0
4/0-7/W .1739 653.3 1250-91/W .1172 3859.0
4/0-19/W .1055 653.3 1500-61/W .1568 4631.0
250-19/W .1147 771.9 1500-91/W .1284 4631.0
Back to top of page
BARE COPPER 25 POUND HANDI-PAK
SOFT-DRAWN GROUND WIRE

DESCRIPTION
Bare copper conductors available in various tempers and sizes. Coated copper conductors, solid or stranded, available in various sizes but in soft temper only.

APPLICATION
Used in overhead electrical transmission and distribution, for grounding electrical systems where high conductivity and flexibility is required. Suitable for numerous other applications.

SPECIFICATION
ASTM B-1 Hard-Drawn Copper Wire
ASTM B-2 Medium-Hard-Drawn Copper Wire
ASTM B-3 Soft or Annealed Copper Wire
ASTM B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft
ASTM B-33 Tinned Soft or Annealed Copper Wire
Size Stranding Spool Length (Ft.) Size Stranding Spool Length (Ft.)
22 Solid 12,885 6 Solid 315
20 Solid 8,064 4 Solid 198
18 Solid 5,828 2 Solid 124
16 Solid 3,200 8 7/W 490
14 Solid 2,015 6 7/W 308
12 Solid 1,265 4 7/W 194
10 Solid 795 2 7/W 122
08 Solid 500
 
UTILITY GRADE - DEAD-SOFT ANNEALED
Size Stranding Spool Length (Ft.)
6 Solid 315
4 Solid 198
       
NEHRING ELECTRICAL WORKS CO., DeKalb, Illinois 60115 - 815-756-2741 - 800-435-4481